FBG-M2 Blood Glucose Kit
The M2 blood glucose meter is built for daily self-testing and long-term glucose record keeping. An 8-electrode strip design supports stable readings, while a 0.8 µL sample and 5-second test time make routine checks easier. Bluetooth syncs results to the Fondcircle app for trend tracking. A backlit LCD, strip light, 500-record memory, and rechargeable 250 mAh battery support use at home, while traveling, or in low light.
Features
Multi-point strip sensing supports stable readings for routine glucose checks
Only 0.8 µL of fresh capillary whole blood needed
Get a glucose reading in about 5 seconds
Sync readings and view trends over time
Built-in lithium battery charges by Micro-USB
Backlit LCD and strip light make low-light testing easier
FDA granted 510(k) clearance
FSA & HSA Payments Accepted
30-day risk-free trial
1-Year Warranty
Pairs well with

FBG-M2 Blood Glucose Kit

Built for Repeat Testing
8-Electrode Detection. Stable Routine Readings.
The M2 uses an 8-electrode strip design for multi-point signal collection. This helps resist sample and environment interference, supporting more consistent readings for daily self-testing routines.

Small Sample, Fast Result
TinyDrop Sample
Only 0.8 µL of fresh capillary whole blood is needed, and each reading appears in about 5 seconds. A backlit LCD and strip light make routine checks easier in low-light moments.

Ready for the First Test
A Complete Testing Kit.
The kit includes the meter, 50 test strips, 50 lancets, a lancing device, control solution, storage case, and USB charging cable. Use only compatible strips and close the strip vial immediately after each test.
FondCircle App
Get hospital-level care from home with FondCircle’s tele-health platform and smart devices for accurate, connected health monitoring.
Data Protection
We protect your health.
We also protect your privacy.
The Fondcircle app handles your health data in accordance with HIPAA standards. Your readings stay on your device by default — sharing through CareShare is always initiated by you, and only reaches the people you choose. We do not sell your health data.
Specifications
| Model | FBG-M2 |
| Measurement range | 20–600 mg/dL |
| Measurement unit | mg/dL |
| Sample volume | 0.8 µL |
| Sample type | Fresh capillary whole blood |
| Test time | 5 seconds |
| Memory | 500 readings |
| Connectivity | Bluetooth app sync |
| Display and prompts | Backlit LCD, strip light, beep prompt |
| Power | Built-in 3.7V rechargeable lithium battery |
| Battery capacity | 250 mAh |
| Charging | Micro-USB, 5V |
| Auto power-off | 2 minutes |
| Operating environment | 5°C–45°C / 41°F–113°F 10%–90% RH |
| Test strip storage | 2°C–30°C / 36°F–86°F 10%–90% RH |
| Dimensions | 83 × 52 × 18.7 mm |
| Weight | To be confirmed before publishing |
| Use limitations | Single-patient self-testing only Not for neonatal use Not for diabetes diagnosis or screening |
What's in the Box
- FBG-M2 blood glucose meter × 1
- Control solution × 1
- Test strips × 50
- Lancets × 50
- Lancing device × 1
- Storage case × 1
- USB charging cable × 1
- User manuals × 1 set
FAQs
Please read our FAQs page to find out more.
Is M2 a continuous glucose monitor?
No. M2 is a fingerstick blood glucose meter for self-testing. It is not a CGM, does not provide continuous readings, and does not give medication advice.
What sample does M2 use?
M2 uses fresh capillary whole blood from a fingertip. The current PDP draft lists a 0.8 uL sample and a result time of about 5 seconds.
What is the control solution for?
Control solution is used to check whether the meter and strips are working properly. It should not be described as calibration solution. Follow the meter, strip, and control solution instructions.
How should I handle test strips?
Use compatible FondCircle test strips only. Keep the strip container closed, avoid moisture and contamination, and follow the strip label for the use period after opening. The internal FAQ states 4 months after opening and should be checked against the final U.S. strip label before publishing.
Can I test while charging?
No. The PDP draft states that M2 should not be used for blood glucose testing while charging. If the display is unclear or the meter will not turn on, charge it with Micro-USB before testing.
What should I do if my result seems unusual?
Wash and dry your hands, retest with a new strip, confirm the strip is not expired or contaminated, and check with control solution if needed. If a result is very low, very high, or does not match how you feel, contact a healthcare professional.